Zebronics Zeb-OU3KE6

Incl. TAX

- Free Shipping on orders above ₹5000

Join our waitlist & Get notified once item is in stock

GET LX INDIA APP SKU: SF534H15GFBH4NXHB154 Categories: , , ,
Guaranteed Safe Checkout

Description

ZEBRONICS Online UPS is specifically designed for operations in poor power areas. They provide high power density with long backup time in compact size. It’s ideal for ATMs, banking and other businesses with critical applications. Users could also adjust charging current from 1A to 6A according to different applications. Comprehensive display allows easy monitoring and access of UPS status.

Features

Online Ups-3KVA
Microprocessor Based Control
LCD Display – Load Level, Battery Level, Ac Mode, Battery Mode, Bypass Mode & Fault Indicators
Generator Compatible
Wide Input Voltage Range
External Battery*
Eco Mode For Energy Saving
Zero Transfer Time
Power Management Software
Country of Origin :  China

Specifications

CAPACITY3000 VA / 2400 W
INPUT
Voltage Range
Low Line Transfer160VAC/140VAC/120VAC/110VAC±5%
\ (Ambient Temp.<35°C)
\ ( based on load percentage 100% – 80 % / 80 % – 70 % / 70 – 60 % / 60 % – 0)
Low Line comeback175VAC/155VAC/135VAC/125VAC ± 5 %
\ (Ambient Temp.<35°C)
\ ( based on load percentage 100% – 80 % / 80 % – 70 % / 70 – 60 % / 60 % – 0)
High Line Transfer280 VAC ± 5 %
High Line comeback270 VAC ± 5 %
Frequency Range40Hz ~ 70 Hz
PhaseSingle phase with ground
Power Factor≥ 0.99 @ nominal voltage (input voltage)
OUTPUT
Output voltage200/208/220/230/240VAC
AC Voltage Regulation±1% (Batt. Mode)
Frequency Range47 ~ 53 Hz or 57 ~ 63 Hz (Synchronized Range)
Frequency Range (Batt. Mode)50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz
OverloadAmbient Temp.<35°C
\ 105%~110%: UPS shuts down after 10 minutes at battery mode or transfer to bypass when the utility is normal.
\ 110%~130%: UPS shuts down after 1minute at battery mode or transfer to bypass when the utility is normal.
\ >130%:UPS shuts down after 3seconds at battery mode or transfer to bypass when the utility is normal.
Current Crest Ratio3:1
Harmonic Distortion≤3 % THD (linear load); = 6 % THD (non-linear load)
Transfer Time
AC Mode to Batt.ModeZero
Inverter to Bypass4 ms (Typical)
Waveform (Batt. Mode)Pure Sinewave
EFFICIENCY
AC Mode90%
Battery Mode88%
BATTERY
Numbers6*
Recharge TimeDepending On The Capacity Of External Batteries
Charging Current1.0A/2.0A/4.0A/6.0A
Charging Voltage82.1 VDC ±1%
PHYSICAL
Dimension397 x 145 x 220mm (D x W x H )
Net. Weight7.4 kg
ENVIRONMENT
Operation Humidity20-90 % RH @ 0- 40°C (non-condensing)
Noise LevelLess than 50dBA @ 1 Meter
MANAGEMENT
Smart RS-232 or USBSupports Windows® XP/Vista/7/8/10, Linux, Unix and MAC
Shopping Cart
Scroll to Top