ZEBRONICS Online UPS is specifically designed for operations in poor power areas. They provide high power density with long backup time in compact size. It’s ideal for ATMs, banking and other businesses with critical applications. Users could also adjust charging current from 1A to 6A according to different applications. Comprehensive display allows easy monitoring and access of UPS status.
Features
Online Ups-3KVA | |
Microprocessor Based Control | |
LCD Display – Load Level, Battery Level, Ac Mode, Battery Mode, Bypass Mode & Fault Indicators | |
Generator Compatible | |
Wide Input Voltage Range | |
External Battery* | |
Eco Mode For Energy Saving | |
Zero Transfer Time | |
Power Management Software | |
Country of Origin : China |
Specifications
CAPACITY | 3000 VA / 2400 W | |
INPUT | ||
Voltage Range | ||
Low Line Transfer | 160VAC/140VAC/120VAC/110VAC±5% \ (Ambient Temp.<35°C) \ ( based on load percentage 100% – 80 % / 80 % – 70 % / 70 – 60 % / 60 % – 0) | |
Low Line comeback | 175VAC/155VAC/135VAC/125VAC ± 5 % \ (Ambient Temp.<35°C) \ ( based on load percentage 100% – 80 % / 80 % – 70 % / 70 – 60 % / 60 % – 0) | |
High Line Transfer | 280 VAC ± 5 % | |
High Line comeback | 270 VAC ± 5 % | |
Frequency Range | 40Hz ~ 70 Hz | |
Phase | Single phase with ground | |
Power Factor | ≥ 0.99 @ nominal voltage (input voltage) | |
OUTPUT | ||
Output voltage | 200/208/220/230/240VAC | |
AC Voltage Regulation | ±1% (Batt. Mode) | |
Frequency Range | 47 ~ 53 Hz or 57 ~ 63 Hz (Synchronized Range) | |
Frequency Range (Batt. Mode) | 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz | |
Overload | Ambient Temp.<35°C \ 105%~110%: UPS shuts down after 10 minutes at battery mode or transfer to bypass when the utility is normal. \ 110%~130%: UPS shuts down after 1minute at battery mode or transfer to bypass when the utility is normal. \ >130%:UPS shuts down after 3seconds at battery mode or transfer to bypass when the utility is normal. | |
Current Crest Ratio | 3:1 | |
Harmonic Distortion | ≤3 % THD (linear load); = 6 % THD (non-linear load) | |
Transfer Time | ||
AC Mode to Batt.Mode | Zero | |
Inverter to Bypass | 4 ms (Typical) | |
Waveform (Batt. Mode) | Pure Sinewave | |
EFFICIENCY | ||
AC Mode | 90% | |
Battery Mode | 88% | |
BATTERY | ||
Numbers | 6* | |
Recharge Time | Depending On The Capacity Of External Batteries | |
Charging Current | 1.0A/2.0A/4.0A/6.0A | |
Charging Voltage | 82.1 VDC ±1% | |
PHYSICAL | ||
Dimension | 397 x 145 x 220mm (D x W x H ) | |
Net. Weight | 7.4 kg | |
ENVIRONMENT | ||
Operation Humidity | 20-90 % RH @ 0- 40°C (non-condensing) | |
Noise Level | Less than 50dBA @ 1 Meter | |
MANAGEMENT | ||
Smart RS-232 or USB | Supports Windows® XP/Vista/7/8/10, Linux, Unix and MAC |